Uninterruptible Power Systems (UPS)

Systems from 500VA to 40KVA

 
Powerware 9104

Powerware Selection Guide

Brochure

   

Warranty

   
 
Specifications

Rating:

3.1 - 6 KVA

Voltage:

High and low voltage models available (see brochure for details)

Frequency:

50/60 Hz

Configuration:

Internal batteries; External extended battery pack available

Topology:

Dual Conversion Online

 
Model Numbers

Model

Part Number

Power Rating

PW9104 3.1

RST31 

3kVA/2.1kW

PW9104 3.1 RM

RSR31 

3kVA/2.1kW

PW9104 3.1 HV

RST32 

3kVA/2.1kW

PW9104 3.1 RM HV

RSR32 

3kVA/2.1kW

PW9104 5.2

RST52 

5kVA/3.5kW

PW9104 6.0

RST62 

6kVA/4.2kW

 

 
Special Features
  • Uninterruptible power protection against power failures, power sags, power surges, brownouts, line noise, high voltage spikes, frequency variation, switching transients and harmonic distortion

  • Advanced Battery Management (ABM™) - doubles battery service life

  • Bundled with power management software - ensures data integrity

  • Standard Automatic Bypass Switch - prevents your equipment from crashing

  • Advanced Power Isolation - for clean output voltage

  • Warranty (US and Canada)

    • 2-year Limited Warranty 

    • 10-year Pro-Rated Warranty

    • $25,000 Load Protection Guarantee

 
Specification Overview
  • Rating: Double Conversion Online Technology provides reliable operation

  • Advanced Battery Management (ABM™) doubles battery service life

  • Standard Automatic Bypass Switch - prevents equipment from crashing

  • Bundled with LanSafe III/FailSafe III power management software to ensure data integrity

  • Advanced Power Isolation for clean output voltage

  • Expandable Power Levels for future system expansion

  • Wide selection of system enhancing options

  • Engine generator compatible to ensure data integrity

 
System Enhancing Options
  • Extended Battery Packs housed in separate, matching cabinets provide extended backup time. Up to three battery cabinets may be daisy-chained with easy "plug and play" connections for more extended time. Battery packs for the rack-mount models, like the main UPS units, fit in standard 19-inch equipment racks. To provide maximum flexibility, batteries for the international RSi models come in separate battery packs.

  • Second RS-232 Interface on rear panel allows UPS to communicate with two different platforms independently.

  • Remote Power Warning Cable Interface Kits enable the UPS to initiate a shutdown in the event of a power failure. A 25-foot cable is provided. The interface accommodates AS/400 as well as other operating system platforms.

  • Start-On-Battery allows startup of the computer network from the UPS battery in the event of AC line failure.

  • Remote Distribution Receptacle Box is available with individually protected circuits and an eight-foot line cord that plugs directly into the rear of the UPS. An LI4-30R receptacle plate must be installed on the UPS to use this option.

  • Rack-Mount units are available for the North American 3.1 KVA models (RS) and all international models (RSi). The unit is supplied with mounting brackets for easy installation into a standard 19-inch electronic equipment rack. The front panel on the rack configuration is mounted horizontally with all the controls and functions identical to the standard tower models.

  • Maintenance Bypass Switch (Panel Option) allows input voltage to bypass the UPS and go directly to the connected equipment if an abnormal condition prevents the UPS from supporting the load.