Uninterruptible Power Systems (UPS)

Systems from 500VA to 40KVA

 
Powerware 9305

Powerware Selection Guide

Brochure

   

Specifications, 7.5-15KVA

   

Specifications, 25-45KVA

   
 
Special Features
  • Uninterruptible power protection against power failures, power sags, power surges, brownouts, line noise, high voltage spikes, frequency variation, ups, switching transients and harmonic distortion

  • Advanced Battery Management (ABM™) - doubles battery service life

  • LanSafe III compatible - an easy and complete power management solution

  • Silent - Ideal for server rooms

  • DC Expert™ - accurate remaining back-up time indication

 
Specification Overview (7.5 to 15KVA) 
  • Double Conversion Topology ensures trouble free output.

  • 3-Phase UPS with 3-Phase Bypass ensures balanced loading of the mains also in bypass.

  • Widest Input Voltage and Frequency Window in the Market means longer battery life and increased reliability.

  • Continuous 100% Unbalanced Loading means that loads can be started and stopped without worrying about balancing.

  • On-site Upgrading Possible means that the customer can later increase the load without buying a new UPS.

  • Input Power Factor of 0.96 means smaller fuses are used, ensuring a more cost effective installation.

  • Selectable Output Voltage ensures excellent output voltage properties for demanding situations.

  • Communication Interfaces allow serial communication with local computers and remote computers via modem. The relay interface allows building monitoring.

  • LanSafe III Compatibility for an easy and complete power management solution.

  • Sentinel FORS Compatibility for remote monitoring by service centers.

  • PowerVision® Compatibility for top of the line monitoring and trend analysis software for monitoring all components from UPS's and generators to utility and power distribution (the whole power train).

  • Advanced Battery Management (ABM™). Since the UPS charges the batteries only when necessary, the temperature of the batteries is lower and corrosion is lessened, allowing a 50% longer life time for the batteries. On-line remote monitoring during rest mode, safe test means that the UPS doesn't switch to battery mode and the load will not crash in case of faulty battery. Test results and Advanced Battery Management™ status availability via local and remote monitoring ensures early warning for the customer and the service. In case of faulty battery, the early warning gives enough time for the customer to change the battery bank before it becomes useless.

  • DC Expert™ "learns" the battery and takes aging into account, ensuring an accurate remaining back-up time indication.

  • Size. The unit is small, light, equipped with castors and has a very small foot print making it ideal for a server room. It is easy to move and install.

  • Robust Design makes this UPS ideal for industrial environments.

  • Ease of Use. LED's indicate the status of the UPS and there is one-switch operation.

  • Battery Start means that it can be started also when the mains is missing.

  • Silent makes this UPS ideal for server rooms.

 
Specification Overview (25 to 45KVA)
  • Double Conversion Topology ensures trouble-free output.

  • 3-Phase UPS with 3-Phase Bypass ensures balanced loading of the mains also in bypass.

  • Widest Input Voltage and Frequency Window in the Market means longer battery life and increased reliability.

  • Continuous 100% Unbalanced Loading means that loads can be started and stopped without worrying about balancing.

  • On-site Upgrading Possible means that the customer can later increase the load without buying a new UPS.

  • Input Power Factor of 0.96 means smaller fuses are used, ensuring a more cost effective installation.

  • Selectable Output Voltage ensures excellent output voltage properties for demanding situations

  • Communication Interfaces allow serial communication with local computers and remote computers via modem. The relay interface allows building monitoring.

  • LanSafe III Compatibility for an easy and complete power management solution.

  • Sentinel FORS Compatibility for remote monitoring by service centers.

  • PowerVision® Compatibility for top of the line monitoring and trend analysis software for monitoring all components from UPS's and generators to utility and power distribution (the whole power train).

  • Programmable Building Alarms gives flexibility in meeting site/application specific demands.

  • Advanced Battery Management (ABM™). Since the UPS charges the batteries only when necessary, the temperature of the batteries is lower and corrosion is lessened, allowing a 50% longer life time for the batteries. On-line remote monitoring during rest mode, safe test means that the UPS doesn't switch to battery mode and the load will not crash in case of faulty battery. Test results and Advanced Battery Management™ status availability via local and remote monitoring ensures early warning for the customer and the service. In case of faulty battery, the early warning gives enough time for the customer to change the battery bank before it becomes useless

  • DC Expert™ "learns" the battery and takes aging into account, ensuring an accurate remaining back-up time indication.

  • Size. The unit is small, light, equipped with castors and has a very small foot print making it ideal for a server room. It is easy to move and install.

  • Robust Design makes this UPS ideal for industrial environments.

  • Front Access for installation and service

  • Ease of Use. LED's indicate the status of the UPS and there is one-switch operation.

  • Battery Start means that it can be started also when the mains is missing.